Electrical shunt
Electrical shunt > DMCCTBTI
DMCCTBTI
Earthing and short-circuiting device for industrial LV switchboards, IP2X
Technical sheet
/ Standards
IEC 61230
/ Technical specifications

Max Isc : 4,2 kA/1s

The device is composed of :

• 5 micro-clamps TW 2170

Current : 200A AC

Insulated clamp for connection on :

- hexagonal heads of bolts 10 mm

- vertical or horizontal round bar Ø 6 mm to Ø 12 mm

- power bar horizontal or vertical flat 5 mm thick

- rod Ø 10 mm in the axis of the clamp

• 1 quadrifurcation made of :

- 4 copper short-circuiting cables 16 mm² length 0,5 m

- 1 copper earthing cable 16 mm² length 2,5 m

The complete device is delivered in a transport cover HTAGDC.

Optional : Adapters - Smooth terminals

Brass smooth terminals for positioning shunts (live working) or earthing and short-circuiting equipment on LV switchboards terminals sets.

Product reference Dimensions (mm) - 11019 Dimensions (mm) Poids (kg) Conditionnement Désignation Icc Weight (kg) - 11394 Version Technical sheet
DMCCTBTI - 500 x 200 x 100 4 housse HTAGDC Dispositif de mise à la terre et en court-circuit pour tableaux BT en industrie 4,6 ka/1s - IP2X
DMCCTBTI25 - 500 x 200 x 100 4,5 housse HTAGDC - 6 kA/1s - 9 kA/0,5s - IP2X
DMCCTBTI35 - 500 x 200 x 100 5 housse HTAGDC - 7 kA/1s - 13 kA/0,5s - IP2X
DMCCTBTIX 350 x 300 x 100 - - caisse plastique CTS38 Dispositif de mise à la terre et en court-circuit pour tableaux BT en industrie 4,6 ka/1s 3,5 NON IP2X
DMCCTBTX25 - 350 x 300 x 100 4,5 caisse plastique CTS38 - 6 kA/1s - 9 kA/0,5s - NON IP2X