Control and measurement advices
Control and measurement advices > Série 12000

Série 12000

Ø4 mm lead with fuse
Technical sheet
Pulse 32 Darkbg
/ Standards
1000V CAT IV COMPLIANT, REINFORCED INSULATION, DEGREE OF POLLUTION 3, ACCORDING TO EN/IEC 61010-031:2008 ACCORDING TO LCIE REPORT 126340-653092-B. COMPLIANT WITH EUROPEAN DIRECTIVES DBT 2006/95/EC AND ROHS 2011/65/EU AND CE MARKING.
/ Use

Ø4mm lead with fuse for connection to test and measuring instruments such as multimeters. The tip end has a fuse to allow connection close to the source of hazardous voltage so as to protect the user and/or the device located downstream from the source. That design reduces the risks of injury and/or damage due to accidental short circuits.

If the fuse blows, it can be replaced simply by unscrewing the Ø4mm tip end.

/ Technical specifications

Type 12300

Lead : Fused Ø 4 mm male straight plug to Ø4 mm male straight plug. Cross-section : 1 mm² , PVC double insulated

Length : 100 cm

Weight : 55 g

Protection : Fuse 1A HPC@50kA, Ø6x32 mm.

Dedicated voltage : 1000V CAT IV

Dedicated intensity : 10A max. (according to the fuse used).

Operating temperature : 0°C to +40°C

Type 12400

Lead : Fused Ø 4 mm male straight plug to Ø4 mm male 90° bent plug. Cross-section : 1 mm² , PVC double insulated

Length : 100 cm

Weight : 55 g

Protection : Fuse 1A HPC@50kA, Ø6mm x 32mm.

Dedicated voltage : 1000V CAT IV

Dedicated intensity : 10A max. (according to the fuse used).

Operating temperature : 0°C to +40°C